Welcome to Oshino Lamps UK Ltd

Compare Products You have no items to compare.

NDIR Sensor Lamps

NVIS Filters

Filament lamps for use in spectroscopic infrared gas sensors  most often used measuring carbon dioxide (CO2) in a gaseous environment by its characteristic absorption. Applications for NDIR Gas Sensors include devices for monitoring of indoor air quality, gas leak detection, landfill gas monitoring, hazardous area warning signals, automotive and flue gas emissions and patient monitoring for anaesthesiology, amongst others.

Oshino NDIR lamps provide high IR output, accurate filament position, small size long lifetime, and a low thermal time constant.

NDIR Lamps

17 Item(s)

per page

Set Descending Direction
  1. NDIR Sensor Lamp OL-6803TPL-200 T-3/4 WT

    NDIR Sensor Lamp OL-6803TPL-200 T-3/4 WT OL-6803TPL-200

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-6803TPL-200 2.26mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.03
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  2. NDIR Sensor Lamp OL-680TPL-200 T-1 WT

    NDIR Sensor Lamp OL-680TPL-200 T-1 WT OL-680TPL-200

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-680TPL-200 3.00mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.03
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  3. NDIR Sensor Lamp OL-6833TPL-200 T-3/4 WT

    NDIR Sensor Lamp OL-6833TPL-200 T-3/4 WT OL-6833TPL-T34-200

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-6833TPL-T34-200 2.26mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.05
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  4. NDIR Sensor Lamp OL-683TPL-200 T-1 WT

    NDIR Sensor Lamp OL-683TPL-200 T-1 WT OL-683TPL-200

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-683TPL-200 3.00mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.05
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  5. NDIR Sensor Lamp OL-7153 IBPS-200 T-3/4

    NDIR Sensor Lamp OL-7153 IBPS-200 T-3/4 OL-7153IBPS-200

    Wire Terminal(IBPS)
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-7153IBPS-200 2.26mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  6. NDIR Sensor Lamp OL-7153 TPL-100 T-3/4

    NDIR Sensor Lamp OL-7153 TPL-100 T-3/4 OL-7153TPL-100

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-7153TPL-100 2.26mm Dia. CC-6 - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  7. NDIR Sensor Lamp OL-7153 TPL-200 T-3/4

    NDIR Sensor Lamp OL-7153 TPL-200 T-3/4 OL-7153TPL-200

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-7153TPL-200 2.26mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  8. NDIR Sensor Lamp OL-715TPL-100 T-1

    NDIR Sensor Lamp OL-715TPL-100 T-1 OL-715TPL-100-T1

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-715TPL-100-T1 3.00mm Dia. CC-6 - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  9. NDIR Sensor Lamp OL-715TPL-200 T-1

    NDIR Sensor Lamp OL-715TPL-200 T-1 OL-715TPL-200

    Wire Terminal
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-715TPL-200 3.00mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  10. NDIR Sensor Lamp OL-8270 BP-100 T-3/4

    NDIR Sensor Lamp OL-8270 BP-100 T-3/4 OL-8270BP-100

    Bi-Pin
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-8270BP-100 2.26mm Dia. CC-6 - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  11. NDIR Sensor Lamp OL-8270 BP-200 T-3/4

    NDIR Sensor Lamp OL-8270 BP-200 T-3/4 OL-8270BP-200

    Bi-Pin
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-8270BP-200 2.26mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  12. NDIR Sensor Lamp OL-8587 BP-200 T-3/4

    NDIR Sensor Lamp OL-8587 BP-200 T-3/4 OL-8587BP-200

    Bi-Pin
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-8587BP-200 2.26mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.05
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  13. NDIR Sensor Lamp OL-8913 BP-200 T-3/4

    NDIR Sensor Lamp OL-8913 BP-200 T-3/4 OL-8913BP-200

    Bi-Pin
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL-8913BP-200 2.26mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.03
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  14. NDIR Sensor Lamp OL-682 BPE-200 Bi-Pin T-1

    NDIR Sensor Lamp OL-682 BPE-200 Bi-Pin T-1 OL682BPE-200

    Bi-Pin(Type-E)
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL682BPE-200 3.00mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.03
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  15. NDIR Sensor Lamp OL-685 BPE-200 Bi-Pin T-1

    NDIR Sensor Lamp OL-685 BPE-200 Bi-Pin T-1 OL685BPE-200

    Bi-Pin(Type-E)
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL685BPE-200 3.00mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 60 - 0.05
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  16. NDIR Sensor Lamp OL-718 BPE-100 Bi-Pin T-1

    NDIR Sensor Lamp OL-718 BPE-100 Bi-Pin T-1 OL718BPE-100

    Bi-Pin(Type-E)
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL718BPE-100 3.00mm Dia. CC-6 - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))
  17. NDIR Sensor Lamp OL-718 BPE-200 Bi-Pin T-1

    NDIR Sensor Lamp OL-718 BPE-200 Bi-Pin T-1 OL718BPE-200

    Bi-Pin(Type-E)
    Part No. Bulb size Filament Type Bulb thickness (tube) mm Bulb thickness (top) mm
    OL718BPE-200 3.00mm Dia. C-2R - -
    Dimensions mm Voltage V Amps mA Watts W Luminous Intensity (MSCP) cd
    See drawings 5 115 - 0.15
    IR Rise-up time mSec Life hours (1) Continuous ON hours (2) One minute ON One minute OFF hours
    - 40,000 (5VAC) 20,000 (5VDC(1)) 10,000 (5VDC(2))

17 Item(s)

per page

Set Descending Direction